Number of devices: 14
Product group: Atomic Absorption Spectrometers (Flame) (Search all product categories)
Page: 1
Products per page: 10 20 50
Page: 1
▲ Top of page
Product group: Atomic Absorption Spectrometers (Flame) (Search all product categories)
Page: 1
Products per page: 10 20 50
20367
Varian SpectrAA 220 FS
Varian Flame AAS 220 FS. Burner for Ac/Air and Ac/N2O. Can be used up to 4 lamps. 230 V. 50/60 Hz. IEEE. SPS 5 with control module, peristaltic pump, tray type A and type 25. Computer. TFT monitor. Keyboard. Pre-installed software

Be the first to comment
Varian Flame AAS 220 FS. Burner for Ac/Air and Ac/N2O. Can be used up to 4 lamps. 230 V. 50/60 Hz. IEEE. SPS 5 with control module, peristaltic pump, tray type A and type 25. Computer. TFT monitor. Keyboard. Pre-installed software
Product group: Atomic Absorption Spectrometers (Flame)
Stock unit 
Be the first to comment
Price: 6,500.00 €
(excluding VAT)
(excluding VAT)
20319
GBC SensAA Dual
GBC AAS SensAA Dual. Acetylen burner. Operating field. Computer. Software. YoC 2005. Lamps available at inquiry.

Be the first to comment
GBC AAS SensAA Dual. Acetylen burner. Operating field. Computer. Software. YoC 2005. Lamps available at inquiry.
Product group: Atomic Absorption Spectrometers (Flame)
Provider 
Be the first to comment
Price: 9,900.00 €
(excluding VAT)
(excluding VAT)
19763
Perkin Elmer AAS 2100
Perkin Elmer AAS 2100. Air/acetylene burner, 10 cm. FIAS 200. Oven for amalgam system with cuvette. 4-fold lamp changer. Computer. Monitor. Software. 220 V. 50/60 Hz. 350 W

Be the first to comment
Perkin Elmer AAS 2100. Air/acetylene burner, 10 cm. FIAS 200. Oven for amalgam system with cuvette. 4-fold lamp changer. Computer. Monitor. Software. 220 V. 50/60 Hz. 350 W
Product group: Atomic Absorption Spectrometers (Flame)
Stock unit 
Be the first to comment
Price: 4,800.00 €
(excluding VAT)
(excluding VAT)
19698
Perkin Elmer AAnalyst 300
Perkin Elmer Flame AAS AAnalyst 300. 6-fold lamp changer. D2-underground compensation. PC Dell Optiplex GX1. Monitor. HP printer. Software. All lampes available at inquiry.

Be the first to comment
Perkin Elmer Flame AAS AAnalyst 300. 6-fold lamp changer. D2-underground compensation. PC Dell Optiplex GX1. Monitor. HP printer. Software. All lampes available at inquiry.
Product group: Atomic Absorption Spectrometers (Flame)
Provider 
Be the first to comment
Price: 9,800.00 €
(excluding VAT)
(excluding VAT)
19327
Perkin Elmer AAnalyst 300
Perkin Elmer Flame AAS AAnalyst 300. Autosampler AS 90. Diluter Autoprep 50. Dell computer. Printer EPL 550. Software for control and evaluation AAWinlab V 2.61. WIN 95. Last maintenance in September 2008. Equipment in use to the water analysis until June 2010. Option: all lamps available at inquiry.

Be the first to comment
Perkin Elmer Flame AAS AAnalyst 300. Autosampler AS 90. Diluter Autoprep 50. Dell computer. Printer EPL 550. Software for control and evaluation AAWinlab V 2.61. WIN 95. Last maintenance in September 2008. Equipment in use to the water analysis until June 2010. Option: all lamps available at inquiry.
Product group: Atomic Absorption Spectrometers (Flame)
Provider 
Be the first to comment
Price: 6,500.00 €
(excluding VAT)
(excluding VAT)
18800
Varian SpectrAA 300
Varian Flame-AAS SpectrAA 300. With air/acetylene burner. 230 V. 50 Hz. 3 A. With Autosampler PSC-56. Tray with 67 positions. 4-fold lamp changer. Varian software SpectrAA 300/400 V.1.0 menue and Report Manager.

Be the first to comment
Varian Flame-AAS SpectrAA 300. With air/acetylene burner. 230 V. 50 Hz. 3 A. With Autosampler PSC-56. Tray with 67 positions. 4-fold lamp changer. Varian software SpectrAA 300/400 V.1.0 menue and Report Manager.
Product group: Atomic Absorption Spectrometers (Flame)
Stock unit 
Be the first to comment
Price: 4,900.00 €
(excluding VAT)
(excluding VAT)
18386
Perkin Elmer 3030B
Perkin Elmer Flame-AAS 3030 B. Burner for acetylene/air and acetylene/laughing gas. System disk. Operating panel and monitor integrated. 4-fold lamp changer. Possible for EDL and HKL.

Be the first to comment
Perkin Elmer Flame-AAS 3030 B. Burner for acetylene/air and acetylene/laughing gas. System disk. Operating panel and monitor integrated. 4-fold lamp changer. Possible for EDL and HKL.
Product group: Atomic Absorption Spectrometers (Flame)
Stock unit 
Be the first to comment
Price: 4,200.00 €
(excluding VAT)
(excluding VAT)
18203
Perkin Elmer 1100B
Perkin Elmer AAS 1100B. Flame. With air-acetylene burner. Screen and control panel integrated. Only ever use a lamp. Atomizer B050480. 230 V. 50 Hz. 250 W. Optional: All lamps at inquiry available

Be the first to comment
Perkin Elmer AAS 1100B. Flame. With air-acetylene burner. Screen and control panel integrated. Only ever use a lamp. Atomizer B050480. 230 V. 50 Hz. 250 W. Optional: All lamps at inquiry available
Product group: Atomic Absorption Spectrometers (Flame)
Stock unit 
Be the first to comment
Price: 5,300.00 €
(excluding VAT)
(excluding VAT)
18077
Analytik Jena Vario 6
Analytik Jena AAS Vario 6. Flame. Automatic autosampler. Burner: acetylene/air and acetylene/laughing gas. 230 V. 50 Hz. 120 W. Pentium-III-computer. Monitor. Software WinAAS V.1.7.

Be the first to comment
Analytik Jena AAS Vario 6. Flame. Automatic autosampler. Burner: acetylene/air and acetylene/laughing gas. 230 V. 50 Hz. 120 W. Pentium-III-computer. Monitor. Software WinAAS V.1.7.
Product group: Atomic Absorption Spectrometers (Flame)
Stock unit 
Be the first to comment
Price: 7,500.00 €
(excluding VAT)
(excluding VAT)
18035
Unicam Solaar 969
Unicam AAS Solaar 969 MK II. Flame. Acetylene/air burner. Software version 2.06 for analyse and control of the device. System Win95. Few factory hours. Option: All lamps at inquiry available.

Be the first to comment
Unicam AAS Solaar 969 MK II. Flame. Acetylene/air burner. Software version 2.06 for analyse and control of the device. System Win95. Few factory hours. Option: All lamps at inquiry available.
Product group: Atomic Absorption Spectrometers (Flame)
Provider 
Be the first to comment
Price: 7,800.00 €
(excluding VAT)
(excluding VAT)
17173
Analytik Jena Vario 6
Analytik Jena AAS Vario 6. Only Flame. Actetylen/laughing-gas burner. Autosampler AS-52 for up to 77 samples. Pressure reducer for laughing gas, 300/10 bar. Software WinAAS V.3.3 on CDRom. Waste bottle. Computer. 230 V. 50 Hz. 180 W. Optional: all lamps at inquiry.

Be the first to comment
Analytik Jena AAS Vario 6. Only Flame. Actetylen/laughing-gas burner. Autosampler AS-52 for up to 77 samples. Pressure reducer for laughing gas, 300/10 bar. Software WinAAS V.3.3 on CDRom. Waste bottle. Computer. 230 V. 50 Hz. 180 W. Optional: all lamps at inquiry.
Product group: Atomic Absorption Spectrometers (Flame)
Stock unit 
Be the first to comment
Price: 9,800.00 €
(excluding VAT)
(excluding VAT)
16073
Perkin Elmer 5100 PC
Perkin Elmer FIMS AAS 5100 PC. Perkin Elmer FIAS 200. Autosampler AS 90. Tray B. 6-fold Lampchanger. Option: All lamps can be ordered on request.

Be the first to comment
Perkin Elmer FIMS AAS 5100 PC. Perkin Elmer FIAS 200. Autosampler AS 90. Tray B. 6-fold Lampchanger. Option: All lamps can be ordered on request.
Product group: Atomic Absorption Spectrometers (Flame)
Stock unit 
Be the first to comment
Price: 4,500.00 €
(excluding VAT)
(excluding VAT)
15817
Perkin Elmer 2100
Perkin Elmer AAS 2100. Flame with AC/N202-burner. 4-fold Lamp changer. Graphite oven HGA 700. Autosampler AS 70. Computer. Monitor. All lamps available at inquiry.

Be the first to comment
Perkin Elmer AAS 2100. Flame with AC/N202-burner. 4-fold Lamp changer. Graphite oven HGA 700. Autosampler AS 70. Computer. Monitor. All lamps available at inquiry.
Product group: Atomic Absorption Spectrometers (Flame)
Stock unit 
Be the first to comment
Price: 4,800.00 €
(excluding VAT)
(excluding VAT)
14685
Analytik Jena Vario 6 FL
Analytik Jena Flame AAS Vario 6 FL. Autosampler AS 52 S. Acetylen burner and laughing gas burner 50mm. Software WinAAS 3.91. YoC 2000.

Be the first to comment
Analytik Jena Flame AAS Vario 6 FL. Autosampler AS 52 S. Acetylen burner and laughing gas burner 50mm. Software WinAAS 3.91. YoC 2000.
Product group: Atomic Absorption Spectrometers (Flame)
Stock unit 
Be the first to comment
Price: 8,500.00 €
(excluding VAT)
(excluding VAT)
Page: 1
▲ Top of page
Atomic Absorption Spectrometers (Flame)
Atomic absorption spectroscopy (AAS) is the summary of spectroscopic processes, which can be used for the quantitative and qualitative analyses of elements in watery solutions and in solids. Basically, atomic absorption spectroscopy represents a part of analytic chemistry.Classification of atomic absorption spectrometry
Atomic absorption spectrometry can be classified as follows: flame atomic absorption spectrometry (F-AAS), graphite furnace atomic absorption spectrometry with electrothermal heating (GF-AAS), cold vapour atomic absorption spectrometry (CV-AAS) and atomic absorption spectrometry with continuum source and high-resolution Echelle double monochromator (HR-CS-AAS).Functionality of an atomic absorption spectrometer
For AAS, a light source emits light of different wavelengths and a defined intensity. An atomisation device in which the components of an analyte are atomised, i. e., converted into the state of single, excitable atoms, is in the optical path of the atomic absorption spectrometer. This atomisation can be achieved either by a flame of gas (a mixture of acetylene/air or acetylene/nitrogen oxide), into which the analyte solution will be sprayed, or by strong heating in a graphite tube. The intensity of the attenuated beam of light is measured behind the atomisation device and compared to that of the unattenuated light. Detection follows, observing how much of the irradiated light of a defined wavelength has been absorbed by the element of the analyte. The Lambert-Beer law applies here, stating that the concentration of the analyte is directly proportional to the attenuation of the irradiated light. The light energy that was absorbed during this process is emitted again by the atom that had been excited this way. This is the so-called fluorescence.Light source of an atomic absorption spectrometer
Different light sources can be applied in atomic absorption spectrometry. The hollow-cathode lamp consists of a cathode which is composed of the element of the analyte. Superlamps dispose of another, additional cathode. The electrodeless discharging lamp is based on the principle of gas discharge.Atomisation in an atomic absorption spectrometer (flame)
The dissolved sample is first converted into an aerosol. A part of the aerosol is carried into the mixing chamber. Here the solvent evaporates, and the solid components of the sample are melted, evaporated and dissociated.Literatur
- http://de.wikipedia.org/w/index.php?title=Atomspektroskopie&oldid=85044962 (called: 30.03.11).
- http://de.wikipedia.org/w/index.php?title=Atomabsorptionsspektrometrie&oldid=86725842 (called: 30.03.11).
- http://www.chemgapedia.de/vsengine/vlu/vsc/de/ch/16/anac/aaseinf.vlu.html (called: 30.03.11).
- http://www.chemgapedia.de/vsengine/vlu/vsc/de/ch/16/anac/aasanwend.vlu.html (called: 30.03.11).