Number of devices: 11
Product group: Gaschromatographs (FID) (Search all product categories)

Page: 1
Products per page: 10 20 50

20382
Perkin Elmer Clarus 500
Perkin Elmer GC Clarus 500. With FPD-detector. Autosampler. Capillary injector. Capillary columns. PC. Monitor. Software Turbochrom TotalChrom 6.3.1. Licences. YoC 2007
Provider

 (0)  Tags: Perkin Elmer, Clarus 500
Be the first to comment
Price: 10,900.00 €
(excluding VAT)
20301
Thermo Focus GC
Thermo Gas chromatograph Focus GC. FID. Split/splitless injector. Operating field. Display. Serial interface. Chrome Card Software 2.3.3 on CDROM. 230 V. 50/60 Hz. 1.6 kW. CE marked. With Thermo autosampler AI 3000 with 8 positions.
Stock unit

 (0)  Tags: Thermo, Focus GC
Be the first to comment
Price: 6,900.00 €
(excluding VAT)
20294
Perkin Elmer Autosystem XL
Perkin Elmer GC Autosystem XL. Split/spliless Injector. FID. GC for capillary columns. Operating field. Display. 230 V. 50/60 Hz. 2,4 kW. CE marked. Perkin Elmer Nelson interface 950A. Pressure reducer for nitrogen.
Stock unit

 (0)  Tags: Perkin Elmer, Autosystem XL
Be the first to comment
Price: 5,200.00 €
(excluding VAT)
20066
Perkin Elmer Autosystem XL
Perkin Elmer GC Autosystem XL. Detectors: ECD. FID. Ni-63, 560 MBq. Split/splitless injector with PPC. For capillary columns. Turbochrom software, version 4 and update to 4.1. Dongle. Interfaces: serial and GPIB. Operation field. Display. 230 V. 50 Hz. 8 A. 3 pressure reducer 300/40/10 bar for hydrogen, nitrogen, synthetic air. Gas filter cartridge
Stock unit

 (0)  Tags: Perkin Elmer, Autosystem XL
Be the first to comment
Price: 5,900.00 €
(excluding VAT)
19884
Perkin Elmer Clarus 500
Perkin Elmer GC Clarus 500. FID. Capillary injector with PPC. Autosampler with injection tower and sample tray with 82 positions. Display. 230 V. 50/60 Hz. 2,4 kW. CE marked. Without software. YoC 2006
Stock unit

 (0)  Tags: Perkin Elmer, Clarus 500
Be the first to comment
Price: 9,800.00 €
(excluding VAT)
19741
Perkin Elmer Autosystem
Perkin Elmer Gaschromatograph/GC Autosystem. 1-channel. FID. Split/splitless-injector. Operating field. Display. Autoinjector with tray for 81 positions. 230 V. 50 Hz. 2,4 kW. Analogue signals need to be tapped
Stock unit

 (0)  Tags: Perkin Elmer, Autosystem
Be the first to comment
Price: 3,900.00 €
(excluding VAT)
18995
Hewlett Packard 5890 A FID
Hewlett Packard GC 5890A serie II. FID. Split/splitless-injector. 230 V. 50 Hz. 2200 W. Without interfaces . Data output analog. With Hewlett Packard integrator 3390A. 220 V. 50 Hz. Analog output 0-1 V. Operating field.
Stock unit

 (1)  Tags: Hewlett Packard, 5890 A
Price: 3,900.00 €
(excluding VAT)
16778
Perkin Elmer Autosystem
Perkin Elmer GC Autosystem. FID. Split/splitless. Autosampler. Injectiontower. Syringe. Tray with 82 positions. For capillary columns. 1-channel. 230 V. 50 Hz. 6 A. RS-232-interface.
Stock unit

 (0)  Tags: Perkin Elmer, Autosystem
Be the first to comment
Price: 3,900.00 €
(excluding VAT)
15308
Carlo Erba 5160
Carlo Erba GC HRGC 5160. With OC 416. EL 480. MFC 500. FID. Split/splitless. GC for capillary columns.
Stock unit

 (1)  Tags: Carlo Erba, 5160
Price: 4,500.00 €
(excluding VAT)
14393
Hewlett Packard 5890 A
Hewlett Packard GC 5890 A. With FID. NPD. 2 x Injector split/splitless. 230V.
Stock unit

 (0)  Tags: Hewlett Packard, 5890 A
Be the first to comment
Price: 3,900.00 €
(excluding VAT)
12995
Perkin Elmer Autosystem XL
Perkin Elmer GC Autosystem XL. Split/splitless-Injector. FID.
Stock unit

 (0)  Tags: Perkin Elmer, Autosystem XL
Be the first to comment
Price: 6,800.00 €
(excluding VAT)

Page: 1


▲ Top of page

Gaschromatographs (FID)

Gas chromatographs are used for the separation of mixtures with volatile components. The separation process of gas chromatography is based on multiplicative distribution between the mobile and the stationary phase of the mixture, which is carried by the mobile phase through the column. Because of its high efficiency in separation, it is possible to split very complex compounds into their individual components and to analyse them with a detector. Note, however, that gas chromatography concerns gas mixtures or non-decomposed evaporateable substances.

Construction of gas chromatographs

The architecture of a gas chromatographs can be described as follows. A gas chromatograph consists of a carrier gas supply which is filled with the mobile phase, an injector, a column, which is often made of metal or glass, has a length of 10 to 200 metres and is inside a temperable oven, a detector and a data evaluation device whose results a standard computer may display. The mobile phase of gas chromatography is represented by an inert gas, p. e. helium or nitrogen, the stationary phase is represented by adsorbing solids or absorbent liquids. Gas chromatographs can consequently be classified by either a packed column or a capillary column. The rate by which the substance is transported through the column is determined basically by the flowrate of the mobile phase. The function of the stationary phase in gas chromatography is now to separate the sample into its individual components. Capillary column and packed column may be distinguished by their stationary phase. The packed column of gas chromatographs contains a solid support material, coated with a thin, liquid film, i. e. the stationary phase. The capillary column, however, may in gas chromatography be either wall-coated (WCOT column), support-coated (SCOT column) or consist of porous-layer capillaries (PLOT column).

Detectors in gas chromatography

In gas chromatography, different detectors are applied, according to the substance to be examined. Often flame ionisation detectors, thermal ionic detectors, electron capture detectors, thermal conductivity detectors or other detectors are used, such as the mass spectrometer. Often, a combination of several detectors may also be applied.

Literature

  • http://de.wikipedia.org/w/index.php?title=Gaschromatographie&oldid=86925177 (called: 29.03.11).
  • http://www.chemgapedia.de/vsengine/vlu/vsc/de/ch/3/anc/croma/gc_detail1.vlu.html (called: 29.03.11).