Number of devices: 20
Product group: HPLC-Detectors (UV/VIS) (Search all product categories)
Page: 1
Products per page: 10 20 50
Page: 1
▲ Top of page
Product group: HPLC-Detectors (UV/VIS) (Search all product categories)
Page: 1
Products per page: 10 20 50
20035
BioRad 1706
Biorad UV/Vis-detector 1706. For HPLC. 190-600 nm. Double-beam device. Accuracy +/- 2 nm. Recorder output 10 mV/full scale. Integrator output 1 AU/V or 2 AU/V. 220 V. 50 Hz. Max 80 W.

Be the first to comment
Biorad UV/Vis-detector 1706. For HPLC. 190-600 nm. Double-beam device. Accuracy +/- 2 nm. Recorder output 10 mV/full scale. Integrator output 1 AU/V or 2 AU/V. 220 V. 50 Hz. Max 80 W.
Product group: HPLC-Detectors (UV/VIS)
Stock unit 
Be the first to comment
Price: 980.00 €
(excluding VAT)
(excluding VAT)
19730
TSP UV 1000
Spectra Physics programmable UV/Vis-detector UV1000. 190-800 nm. With analytical flow cell, 10 mm, 15 µL. Operating field. Display. 100-240 V. 50/60 Hz. 175 W.

Be the first to comment
Spectra Physics programmable UV/Vis-detector UV1000. 190-800 nm. With analytical flow cell, 10 mm, 15 µL. Operating field. Display. 100-240 V. 50/60 Hz. 175 W.
Product group: HPLC-Detectors (UV/VIS)
Stock unit 
Be the first to comment
Price: 1,280.00 €
(excluding VAT)
(excluding VAT)
19712
Waters 2475
Waters Multi-wavelength fluorescence detector 2475. Programmable. 200-900 nm. Operating field. Display. Analytical cell, max. 10 bar. 100-240 V. 50/60 Hz. 280 W. Connections: I/O, IEEE, RS232, Ethernet. Auto-Zero. Marker function. CE marked. AC: 2002

Be the first to comment
Waters Multi-wavelength fluorescence detector 2475. Programmable. 200-900 nm. Operating field. Display. Analytical cell, max. 10 bar. 100-240 V. 50/60 Hz. 280 W. Connections: I/O, IEEE, RS232, Ethernet. Auto-Zero. Marker function. CE marked. AC: 2002
Product group: HPLC-Detectors (UV/VIS)
Stock unit 
Be the first to comment
Price: 4,900.00 €
(excluding VAT)
(excluding VAT)
19711
Waters 2487
Waters Wavelength-detector 2487. Operating field. Display. Analytical cell, max. 70 bar. 100-240 V. 50/60 Hz. 145 W. Connections: I/O, IEEE, RS232, Auto-Zero. Marker function. CE marked. YoC 2002

Be the first to comment
Waters Wavelength-detector 2487. Operating field. Display. Analytical cell, max. 70 bar. 100-240 V. 50/60 Hz. 145 W. Connections: I/O, IEEE, RS232, Auto-Zero. Marker function. CE marked. YoC 2002
Product group: HPLC-Detectors (UV/VIS)
Stock unit 
Be the first to comment
Price: 2,900.00 €
(excluding VAT)
(excluding VAT)
19707
Waters 2475
Waters Multi-wavelength fluorescence detector 2475. Programmable. 200-900 nm. Operating field. Display. Analytical cell, max. 10 bar. 100-240 V. 50/60 Hz. 280 W. Connections: I/O, IEEE, RS232, Ethernet. Auto-Zero. Marker function. CE marked. AC: 2002

Be the first to comment
Waters Multi-wavelength fluorescence detector 2475. Programmable. 200-900 nm. Operating field. Display. Analytical cell, max. 10 bar. 100-240 V. 50/60 Hz. 280 W. Connections: I/O, IEEE, RS232, Ethernet. Auto-Zero. Marker function. CE marked. AC: 2002
Product group: HPLC-Detectors (UV/VIS)
Stock unit 
Be the first to comment
Price: 4,900.00 €
(excluding VAT)
(excluding VAT)
19485
Knauer Smartline 2500
Knauer UV-detector Smartline 2500. Art. A5140. With flowcell A4042. YoC 2008. Device was about 18 months to March 2011 in the field of organic chemistry at a German university in use.

Be the first to comment
Knauer UV-detector Smartline 2500. Art. A5140. With flowcell A4042. YoC 2008. Device was about 18 months to March 2011 in the field of organic chemistry at a German university in use.
Product group: HPLC-Detectors (UV/VIS)
Provider 
Be the first to comment
Price: 3,700.00 €
(excluding VAT)
(excluding VAT)
19364
Shimadzu SPD-10A
Shimadzu UV/VIS-detector SPD-10A. For HPLC. 190-600 nm. 220 V. 50 Hz. 130 W. 1,6A. Operating field. Digital display. Analog connections. Analytical flow cell. Deuterium lamp

Be the first to comment
Shimadzu UV/VIS-detector SPD-10A. For HPLC. 190-600 nm. 220 V. 50 Hz. 130 W. 1,6A. Operating field. Digital display. Analog connections. Analytical flow cell. Deuterium lamp
Product group: HPLC-Detectors (UV/VIS)
Stock unit 
Be the first to comment
Price: 1,950.00 €
(excluding VAT)
(excluding VAT)
18300
Shimadzu SPD-10A
Shimadzu UV-VIS detector SPD 10A.

Be the first to comment
Shimadzu UV-VIS detector SPD 10A.
Product group: HPLC-Detectors (UV/VIS)
Provider 
Be the first to comment
Price: 1,950.00 €
(excluding VAT)
(excluding VAT)
18050
Waters 486
Waters Tunable absorbance detector 486. For HPLC. Input voltage 100/120/230/240 V.

Be the first to comment
Waters Tunable absorbance detector 486. For HPLC. Input voltage 100/120/230/240 V.
Product group: HPLC-Detectors (UV/VIS)
Provider 
Be the first to comment
Price: 980.00 €
(excluding VAT)
(excluding VAT)
17617
Duratec DDT 3200
Duratec UV/VIS-detector DDT 3200.

Be the first to comment
Duratec UV/VIS-detector DDT 3200.
Product group: HPLC-Detectors (UV/VIS)
Provider 
Be the first to comment
Price: 3,350.00 €
(excluding VAT)
(excluding VAT)
16983
Erma ERC-7215
Erma HPLC UV-detector ERC-7215. For HPLC. 220 V. 50 Hz. 195-350 nm. Digitale indication. Operating field. Analogeous exits for recorders. Analytical measuring cell.

Be the first to comment
Erma HPLC UV-detector ERC-7215. For HPLC. 220 V. 50 Hz. 195-350 nm. Digitale indication. Operating field. Analogeous exits for recorders. Analytical measuring cell.
Product group: HPLC-Detectors (UV/VIS)
Stock unit 
Be the first to comment
Price: 600.00 €
(excluding VAT)
(excluding VAT)
16879
LKB 2138
Pharmacia/LKB UV-detector 2138 Uvicord S. Analytical measuring cell. 220 V. 50 Hz.

Be the first to comment
Pharmacia/LKB UV-detector 2138 Uvicord S. Analytical measuring cell. 220 V. 50 Hz.
Product group: HPLC-Detectors (UV/VIS)
Stock unit 
Be the first to comment
Price: 680.00 €
(excluding VAT)
(excluding VAT)
16102
Milton Roy SpectroMonitor 3100
Milton Roy variable Wavelength-detector SpectroMonitor 3100. For HPLC. 115/220V. Analytical measuring cell. 14 µL. 10mm. 190-700nm. Deuteriumlamp.

Be the first to comment
Milton Roy variable Wavelength-detector SpectroMonitor 3100. For HPLC. 115/220V. Analytical measuring cell. 14 µL. 10mm. 190-700nm. Deuteriumlamp.
Product group: HPLC-Detectors (UV/VIS)
Stock unit 
Be the first to comment
Price: 980.00 €
(excluding VAT)
(excluding VAT)
15310
Kontron 430
Kontron UV/VIS-detector 430. For HPLC. 190-800 nm. Max pressure for cell: 250 bar. Analytical measuring cell: 3 µL. 220 V. 150 W.

Be the first to comment
Kontron UV/VIS-detector 430. For HPLC. 190-800 nm. Max pressure for cell: 250 bar. Analytical measuring cell: 3 µL. 220 V. 150 W.
Product group: HPLC-Detectors (UV/VIS)
Stock unit 
Be the first to comment
Price: 950.00 €
(excluding VAT)
(excluding VAT)
13553
Hitachi 4020
Hitachi UV-Detector Photometer 4020. For HPLC. Stand-alone System. With printer.

Be the first to comment
Hitachi UV-Detector Photometer 4020. For HPLC. Stand-alone System. With printer.
Product group: HPLC-Detectors (UV/VIS)
Stock unit 
Be the first to comment
Price: 950.00 €
(excluding VAT)
(excluding VAT)
13386
Kratos SF 757
Kratos UV/VIS-Detector SF 757. Type Spectroflow. For HPLC. Wavelength 190-700 nm. Bandwidth 5 nm. Accuracy +/- 1 nm. 100-240 V. 50/60 Hz. 85 W. Controls. Display. Analytical flow cell. Stand-alone system.

Be the first to comment
Kratos UV/VIS-Detector SF 757. Type Spectroflow. For HPLC. Wavelength 190-700 nm. Bandwidth 5 nm. Accuracy +/- 1 nm. 100-240 V. 50/60 Hz. 85 W. Controls. Display. Analytical flow cell. Stand-alone system.
Product group: HPLC-Detectors (UV/VIS)
Stock unit 
Be the first to comment
Price: 1,850.00 €
(excluding VAT)
(excluding VAT)
13054
Milton Roy LDC 200
Milton Roy variable Wavelength-detector spectroMonitor D. 220 V. Max 250 W. 190-700 nm. Double beam.

Be the first to comment
Milton Roy variable Wavelength-detector spectroMonitor D. 220 V. Max 250 W. 190-700 nm. Double beam.
Product group: HPLC-Detectors (UV/VIS)
Stock unit 
Be the first to comment
Price: 1,950.00 €
(excluding VAT)
(excluding VAT)
13053
Kontron Uvikon 720
Kontron UV/VIS-Detector Uvikon 720. Programmable. 220 V. 350 W. Interface for RS 232 and printer. Integrated operating field. Flowcell for connection to HPLC. 180-900 nm.

Be the first to comment
Kontron UV/VIS-Detector Uvikon 720. Programmable. 220 V. 350 W. Interface for RS 232 and printer. Integrated operating field. Flowcell for connection to HPLC. 180-900 nm.
Product group: HPLC-Detectors (UV/VIS)
Stock unit 
Be the first to comment
Price: 2,250.00 €
(excluding VAT)
(excluding VAT)
13050
Spectra Physics Spectra 200
Spectra Physics programmable wavelength detector/UV/Vis-detector Spectra SC-200. 190-800 nm. Operating field. Display. Analytical cell, Mod 9550-0100, 6 mm, 9 µL. 100-240 V. 50/60 Hz, 175 W. Interfaces: RS232 serial, analog, Accessory Relay. W-and D2-lamp

Be the first to comment
Spectra Physics programmable wavelength detector/UV/Vis-detector Spectra SC-200. 190-800 nm. Operating field. Display. Analytical cell, Mod 9550-0100, 6 mm, 9 µL. 100-240 V. 50/60 Hz, 175 W. Interfaces: RS232 serial, analog, Accessory Relay. W-and D2-lamp
Product group: HPLC-Detectors (UV/VIS)
Stock unit 
Be the first to comment
Price: 980.00 €
(excluding VAT)
(excluding VAT)
12832
Spectra Physics Spectra 200
Spectra Physics programmable wavelength detector/UV/Vis-detector Spectra SC-200. 190-800 nm. Operating field. Display. Analytical cell, Mod 9550-0100, 6 mm, 9 µL. 100-240 V. 50/60 Hz, 175 W. Interfaces: RS232 serial, analog, Accessory Relay. W-and D2-lamp

Be the first to comment
Spectra Physics programmable wavelength detector/UV/Vis-detector Spectra SC-200. 190-800 nm. Operating field. Display. Analytical cell, Mod 9550-0100, 6 mm, 9 µL. 100-240 V. 50/60 Hz, 175 W. Interfaces: RS232 serial, analog, Accessory Relay. W-and D2-lamp
Product group: HPLC-Detectors (UV/VIS)
Stock unit 
Be the first to comment
Price: 980.00 €
(excluding VAT)
(excluding VAT)
Page: 1
▲ Top of page
HPLC-Detectors (UV/VIS)
HPLC is a physical method to separate, identify and quantify substances by distribution between the mobile, moving and the stationary, steady phase.Functionality of HPLC
HPLC, high performance liquid chromatography, is a separation process where the liquid sample is carried by the liquid phase through the separation column over the stationary phase, on account of high pressure. Length and diameter of the separation column vary according to application. In some cases, a precolumn is placed before the HPLC column to remove impurities before separation. In contrast to gas chromatography, no gaseous or non-decomposed evaporateable substances are necessary for HPLC. In the case of strong interaction of the analyte with the stationary phase, the analyte remains in the column for quite a long time. If there is weak interaction, the opposite case is true: The analyte exits the column quite quickly. Therefore the substances appear at the end of the separation column after different times, the so-called characteristic retention times. HPLC can be differentiated by two principles: normal phase and reversal phase chromatography. In the case of NP-HPLC, a polar stationary phase is used, for example, silicon gel. In this process, the polarity determines the elution force of the mobile phase. The solvents are getting arranged by rising polarity, resulting in the so-called eluotropic series. This means that substances with higher polarity elute faster. Polar molecules better interact with the polar stationary phase and remain therefore longer in the column. RP-HPLC applies a non-polar stationary phase. The elution force decreases with rising polarity.Classification of HPLC
In HPLC, several separation mechanisms can be distinguished, depending on the kind of interaction between stationary phase, mobile phase and the sample: adsorption, partition, ion exchange, size exclusion and bioaffinity chromatography. However, adsorption and partition chromatography are the most common modes of HPLC.Architecture of an HPLC system
An HPLC system consists of an eluent vessel, a degasser, a pump, an injection valve, a precolumn, a column, a detector and an evaluation unit.Literature
- http://de.wikipedia.org/w/index.php?title=Hochleistungsfl%C3%BCssigkeitschromatographie&oldid=86523806 (called: 30.03.11).