Number of devices: 30
Product group: HPLC Systems (Search all product categories)
Page: 1, 2 Next
Products per page: 10 20 50
9800.00 €
30% Discount
up to 29.02.2012
Price: 6,860.00 €
(excluding VAT)
Page: 1, 2 Next
▲ Top of page
Product group: HPLC Systems (Search all product categories)
Page: 1, 2 Next
Products per page: 10 20 50
20258
Hewlett Packard 1050
Hewlett Packard HPLC-system 1050. Variable wavelength-detector 79853C. Operating field. Display. Autosampler. 6-way valve. Tray with 21 positions. Column oven 79856AX. Quarternary pump, operating field, display. Software HPLC 2D ChemStation (DOS-serie), G1304A Rev.A.02.00 on 3,5\"diskettes. 230 V. 50 Hz. About 550 W.

Be the first to comment
Hewlett Packard HPLC-system 1050. Variable wavelength-detector 79853C. Operating field. Display. Autosampler. 6-way valve. Tray with 21 positions. Column oven 79856AX. Quarternary pump, operating field, display. Software HPLC 2D ChemStation (DOS-serie), G1304A Rev.A.02.00 on 3,5\"diskettes. 230 V. 50 Hz. About 550 W.
Product group: HPLC Systems
Stock unit 
Be the first to comment
Price: 5,900.00 €
(excluding VAT)
(excluding VAT)
20018
Agilent HPLC 1100
Agilent/Hewlett Packard HPLC-System 1100. Existing of isocratic pump G1310A. Column oven G1316A. Autosampler G1313A. Variable wavelength detector G1314A. Degasser G1322A. Computer. Software. Licence. Has been used in pharmaceutical laboratory. Complete overhauled.

Agilent/Hewlett Packard HPLC-System 1100. Existing of isocratic pump G1310A. Column oven G1316A. Autosampler G1313A. Variable wavelength detector G1314A. Degasser G1322A. Computer. Software. Licence. Has been used in pharmaceutical laboratory. Complete overhauled.
Product group: HPLC Systems
Provider 
Price: 19,800.00 €
(excluding VAT)
(excluding VAT)
19804
Dionex HPLC-System
Dionex HPLC-system. With gradient pump P 580A HPG. 230 V. 50/60 Hz. 70 W. 0,001-10 mL/min. Binary high pressure gradient. CE marked. Serial interfaces. Autosampler ASI-100. Plate for 117 positions. Injection volume from 0,1 to 250 mL. Max 340 bar. Without tempering. 126 W. 230 V. 50 Hz. Operating field. Display. 6-way valve. Multiple injections possible. With Driver update for version 6.01 to 3.5 \"floppy disk. Fluoreszenz-Detektor/Fluorimeter RF-2000. Xe lamp. 200-650. 4 scanning speeds. 230 V. 50/60 Hz 350 W. Interfaces: nalogous and RS232c. CE marked

Be the first to comment
Dionex HPLC-system. With gradient pump P 580A HPG. 230 V. 50/60 Hz. 70 W. 0,001-10 mL/min. Binary high pressure gradient. CE marked. Serial interfaces. Autosampler ASI-100. Plate for 117 positions. Injection volume from 0,1 to 250 mL. Max 340 bar. Without tempering. 126 W. 230 V. 50 Hz. Operating field. Display. 6-way valve. Multiple injections possible. With Driver update for version 6.01 to 3.5 \"floppy disk. Fluoreszenz-Detektor/Fluorimeter RF-2000. Xe lamp. 200-650. 4 scanning speeds. 230 V. 50/60 Hz 350 W. Interfaces: nalogous and RS232c. CE marked
Product group: HPLC Systems
Stock unit 
Be the first to comment
Price: 7,800.00 €
(excluding VAT)
(excluding VAT)
19756
Thermo Separation HPLC
Thermo Separation HPLC system. Consisting of quaternary pump, P-4000. 0,1-10 mL/min. Max.420 bar. 115/230 V. 50/60 Hz. 200 W. Operating field.Display. Vacuumdegasser SCM 1000. With eluent compartment. Analog pressure gauge. 4 channels. Max 5 mL/min. 110/220 V. 50/60 Hz. 8-channel system controller SN-4000. Autosampler AS-3000. With cooling and heating. Variable loop. Sample preparation. Sample tray for 105 vials. Erma ERC-7515A RI-detector. Control panel. Display. Analog outputs. I/O connector.

Be the first to comment
Thermo Separation HPLC system. Consisting of quaternary pump, P-4000. 0,1-10 mL/min. Max.420 bar. 115/230 V. 50/60 Hz. 200 W. Operating field.Display. Vacuumdegasser SCM 1000. With eluent compartment. Analog pressure gauge. 4 channels. Max 5 mL/min. 110/220 V. 50/60 Hz. 8-channel system controller SN-4000. Autosampler AS-3000. With cooling and heating. Variable loop. Sample preparation. Sample tray for 105 vials. Erma ERC-7515A RI-detector. Control panel. Display. Analog outputs. I/O connector.
Product group: HPLC Systems
Stock unit 
Be the first to comment
Price: 5,900.00 €
(excluding VAT)
(excluding VAT)
19729
Spectra Physics HPLC
Spectra Physics HPLC system. Consisting of: isocratic pump P1000. AS-3500 autosampler with column oven, 6-way valve, 20-µL sample loop, Tray for 105 samples. Optical scanning detector with analytical flow cell FOCUS. All units withoperating field and display. 100-240 V. 50/60 Hz. Add. system controller SN4000.

Be the first to comment
Spectra Physics HPLC system. Consisting of: isocratic pump P1000. AS-3500 autosampler with column oven, 6-way valve, 20-µL sample loop, Tray for 105 samples. Optical scanning detector with analytical flow cell FOCUS. All units withoperating field and display. 100-240 V. 50/60 Hz. Add. system controller SN4000.
Product group: HPLC Systems
Stock unit 
Be the first to comment
Price: 4,400.00 €
(excluding VAT)
(excluding VAT)
19715
Waters 2695
Waters HPLC-system/Separation module 2695. Sampler with 120 positions. Pump. Injection unit SM 7. Furnace module. Display. Operating field. 3,5 \"floppy drive. Connections: analog, RS232, IEEE. 100-240 V. 50/60 Hz. 9,5 A. CE-marked. Holder for solvent bottles. YoC 2002

Be the first to comment
Waters HPLC-system/Separation module 2695. Sampler with 120 positions. Pump. Injection unit SM 7. Furnace module. Display. Operating field. 3,5 \"floppy drive. Connections: analog, RS232, IEEE. 100-240 V. 50/60 Hz. 9,5 A. CE-marked. Holder for solvent bottles. YoC 2002
Product group: HPLC Systems
Stock unit 
Be the first to comment
Price: 9,800.00 €
(excluding VAT)
(excluding VAT)
19630
Perkin Elmer Integral 4000
Perkin Elmer HPLC system Integral 4000. Quarternary pump. Autosampler with 100 positions. Column oven. DAD, 195-365 nm. 4 solvent bottles. Screen. Operating field. 220/240 V. 50/60 Hz. 450 W. Serial printer and communication interface. Monitor output

Be the first to comment
Perkin Elmer HPLC system Integral 4000. Quarternary pump. Autosampler with 100 positions. Column oven. DAD, 195-365 nm. 4 solvent bottles. Screen. Operating field. 220/240 V. 50/60 Hz. 450 W. Serial printer and communication interface. Monitor output
Product group: HPLC Systems
Stock unit 
Be the first to comment
Price: 4,800.00 €
(excluding VAT)
(excluding VAT)
19542
Shimadzu LC 10AvP
Shimadzu HPLC-System complete LC 10 AVP. Consisting of LC-10ADVP micro piston pump with seal wash. Column oven CTO-10ACVPNEW. 4 Channel membrane degasser DGU-14 A. Detector SPD-10AVP, 190-600nm. Fluorescence detector. Autosampler SIL-10ADVP. PC. CLASS VP software 6.1. Single. Control and data analysis. YoC 2004

Be the first to comment
Shimadzu HPLC-System complete LC 10 AVP. Consisting of LC-10ADVP micro piston pump with seal wash. Column oven CTO-10ACVPNEW. 4 Channel membrane degasser DGU-14 A. Detector SPD-10AVP, 190-600nm. Fluorescence detector. Autosampler SIL-10ADVP. PC. CLASS VP software 6.1. Single. Control and data analysis. YoC 2004
Product group: HPLC Systems
Provider 
Be the first to comment
Price: 14,900.00 €
(excluding VAT)
(excluding VAT)
19498
Hewlett Packard HPLC 1050
Hewlett Packard HPLC system 1050. Quarternary pump. Autosampler. Variable wavelength detector.

Be the first to comment
Hewlett Packard HPLC system 1050. Quarternary pump. Autosampler. Variable wavelength detector.
Product group: HPLC Systems
Provider 
Be the first to comment
Price: 6,500.00 €
(excluding VAT)
(excluding VAT)
19490
Agilent HPLC 1100
Agilent HPLC-System 1100. Existing of quarternary pump G1311A. Column oven G1316A. Autosampler G1313A. DAD G1315A. Degasser G1322A. Computer. Software ChemStation A.09.01 preinstalled. Has been used in R&D laboratory in pharmaceutical industry. Complete overhauled. 6 months warranty on pieces.

Agilent HPLC-System 1100. Existing of quarternary pump G1311A. Column oven G1316A. Autosampler G1313A. DAD G1315A. Degasser G1322A. Computer. Software ChemStation A.09.01 preinstalled. Has been used in R&D laboratory in pharmaceutical industry. Complete overhauled. 6 months warranty on pieces.
Product group: HPLC Systems
Provider 
Price: 25,900.00 €
(excluding VAT)
(excluding VAT)
19463
Waters HPLC
Waters HPLC-unit. Consisting of Waters quaternary gradient pump with controller 600S. Waters 717 plus autosampler, sample tray for 96 vials. Waters variable wavelength detector 486. All units: 115/230 V. 50/60 Hz. CE marked. Interfaces: analog, IEEE. Operating field. Display. Without software. YoC 2001

Be the first to comment
Waters HPLC-unit. Consisting of Waters quaternary gradient pump with controller 600S. Waters 717 plus autosampler, sample tray for 96 vials. Waters variable wavelength detector 486. All units: 115/230 V. 50/60 Hz. CE marked. Interfaces: analog, IEEE. Operating field. Display. Without software. YoC 2001
Product group: HPLC Systems
Stock unit 
Be the first to comment
Price: 4,900.00 €
(excluding VAT)
(excluding VAT)
19372
Shimadzu HPLC
Shimadzu HPLC system. Consisting of 2x pump LC10AS. DAD detector SPD-M10AV. Column oven CTO-10 AC. Controller SCL-10A. Autosampler SIL-10A. Computer. Monitor. Canon printer S400. Software LC Workstation Class-LC10, update Vers.1.60. Win 3.1.

Be the first to comment
Shimadzu HPLC system. Consisting of 2x pump LC10AS. DAD detector SPD-M10AV. Column oven CTO-10 AC. Controller SCL-10A. Autosampler SIL-10A. Computer. Monitor. Canon printer S400. Software LC Workstation Class-LC10, update Vers.1.60. Win 3.1.
Product group: HPLC Systems
Stock unit 
Be the first to comment
30% Discount
up to 29.02.2012
Price: 6,860.00 €
(excluding VAT)
19291
Hewlett Packard HPLC 1050
Hewlett Packard/Agilent HPLC-System 1050. Autosampler 1050 for 21 tests. Compressed air, 5 bar required for operation. 6-way valve. Variable wavelength detector 1050, Model 79853A. Standard flow cell. Quaternary pump 1050 0.001 to 9.999 mL/min. DAD 1050. 190-600 nm Solvent Cabinet with 4-channel-helium degasser. Injection valve (Load/Inject). All components: 100-240 V. 50/60 Hz. Max 1000W. HPIB interface. CE marked.

Be the first to comment
Hewlett Packard/Agilent HPLC-System 1050. Autosampler 1050 for 21 tests. Compressed air, 5 bar required for operation. 6-way valve. Variable wavelength detector 1050, Model 79853A. Standard flow cell. Quaternary pump 1050 0.001 to 9.999 mL/min. DAD 1050. 190-600 nm Solvent Cabinet with 4-channel-helium degasser. Injection valve (Load/Inject). All components: 100-240 V. 50/60 Hz. Max 1000W. HPIB interface. CE marked.
Product group: HPLC Systems
Stock unit 
Be the first to comment
Price: 5,500.00 €
(excluding VAT)
(excluding VAT)
19280
Kontron 400
Kontron HPLC-system series 400. Existing of 2x Kontron HPLC-pump 422. Autosampler 465. Tray for 100 vials. Sampler of external temperature-controlled water supply. DAD-detector 440. 100-240 V. 50/60 Hz. CE-marked

Be the first to comment
Kontron HPLC-system series 400. Existing of 2x Kontron HPLC-pump 422. Autosampler 465. Tray for 100 vials. Sampler of external temperature-controlled water supply. DAD-detector 440. 100-240 V. 50/60 Hz. CE-marked
Product group: HPLC Systems
Stock unit 
Be the first to comment
Price: 1,950.00 €
(excluding VAT)
(excluding VAT)
19242
Hewlett Packard 1100
Agilent HPLC system 1100. With Isocratic pump G1310A. Column oven G1316A. Fluorescence detector G1046A. Operating display G1323A. Manual injection valve Rheodyne 7125 with 100 µL sample loop. Computer. Screen. Software pre-installed. 110-120/22-240 V. 50/60 Hz. 1 kW. HPIB interface.

Be the first to comment
Agilent HPLC system 1100. With Isocratic pump G1310A. Column oven G1316A. Fluorescence detector G1046A. Operating display G1323A. Manual injection valve Rheodyne 7125 with 100 µL sample loop. Computer. Screen. Software pre-installed. 110-120/22-240 V. 50/60 Hz. 1 kW. HPIB interface.
Product group: HPLC Systems
Stock unit 
Be the first to comment
Price: 8,900.00 €
(excluding VAT)
(excluding VAT)
19145
Hewlett Packard 1090
Hewlett Packard HPCL-system 1090. DAD. Column oven for max 5 columns. Autosampler with 100 positions. Ternary system. Connection for degassing. 220 V. 750 W. HPIB-interface. Linseis recorder L200E

Be the first to comment
Hewlett Packard HPCL-system 1090. DAD. Column oven for max 5 columns. Autosampler with 100 positions. Ternary system. Connection for degassing. 220 V. 750 W. HPIB-interface. Linseis recorder L200E
Product group: HPLC Systems
Provider 
Be the first to comment
Price: 6,900.00 €
(excluding VAT)
(excluding VAT)
18793
Agilent 1100
Agilent HPLC system 1100. With quarternary pump G1311A. Degaser G1322A. Manual injector G1328A with sample loop, 20 µL. Variable wavelength detector G1314A with standard flowcell. Pentium 1-Computer. Screen. ChemStation Software Rev. A.05.02. Licence BL05072BE3. 110-240 V. 50/60 Hz. CE-marked.

Be the first to comment
Agilent HPLC system 1100. With quarternary pump G1311A. Degaser G1322A. Manual injector G1328A with sample loop, 20 µL. Variable wavelength detector G1314A with standard flowcell. Pentium 1-Computer. Screen. ChemStation Software Rev. A.05.02. Licence BL05072BE3. 110-240 V. 50/60 Hz. CE-marked.
Product group: HPLC Systems
Stock unit 
Be the first to comment
Price: 17,800.00 €
(excluding VAT)
(excluding VAT)
18590
Waters 2695
Waters HPLC 2695. Micromass ZQ. PDA-detector. Vacuumpump. Software Masslynx 4.1. YoC 2001

Be the first to comment
Waters HPLC 2695. Micromass ZQ. PDA-detector. Vacuumpump. Software Masslynx 4.1. YoC 2001
Product group: HPLC Systems
Provider 
Be the first to comment
Price: 39,000.00 €
(excluding VAT)
(excluding VAT)
18372
Shimadzu LC 10AD
Shimadzu gradient HPLC-System LC-10AD. Fraction collector. Column oven CTO 10A. Degaser DGU 3A. Autosampler SIL 10A. UV/VIS-detector SPD 10AV. Conductivity detector CDD 6A. Detector RF 10A.

Be the first to comment
Shimadzu gradient HPLC-System LC-10AD. Fraction collector. Column oven CTO 10A. Degaser DGU 3A. Autosampler SIL 10A. UV/VIS-detector SPD 10AV. Conductivity detector CDD 6A. Detector RF 10A.
Product group: HPLC Systems
Provider 
Be the first to comment
Price: 8,900.00 €
(excluding VAT)
(excluding VAT)
18127
Hewlett Packard 1090L
Hewlett Packard HPLC system 1090 L. Isocratic system. 1 x low-pressure pump. Column oven. Autosampler for max. 100 Vials. DAD 79880 . He-Degasser. 230 V. 50 Hz. Max. 750 W. HPIB interface. PC. Software HPLC 3D ChemStation (DOS series) G1307A, Rev. A. 02.02. Operating fiield. Display.

Be the first to comment
Hewlett Packard HPLC system 1090 L. Isocratic system. 1 x low-pressure pump. Column oven. Autosampler for max. 100 Vials. DAD 79880 . He-Degasser. 230 V. 50 Hz. Max. 750 W. HPIB interface. PC. Software HPLC 3D ChemStation (DOS series) G1307A, Rev. A. 02.02. Operating fiield. Display.
Product group: HPLC Systems
Stock unit 
Be the first to comment
Price: 3,500.00 €
(excluding VAT)
(excluding VAT)
Page: 1, 2 Next
▲ Top of page
HPLC Systems
HPLC is a physical method to separate, identify and quantify substances by distribution between the mobile, moving and the stationary, steady phase.Functionality of HPLC
HPLC, high performance liquid chromatography, is a separation process where the liquid sample is carried by the liquid phase through the separation column over the stationary phase, on account of high pressure. Length and diameter of the separation column vary according to application. In some cases, a precolumn is placed before the HPLC column to remove impurities before separation. In contrast to gas chromatography, no gaseous or non-decomposed evaporateable substances are necessary for HPLC. In the case of strong interaction of the analyte with the stationary phase, the analyte remains in the column for quite a long time. If there is weak interaction, the opposite case is true: The analyte exits the column quite quickly. Therefore the substances appear at the end of the separation column after different times, the so-called characteristic retention times. HPLC can be differentiated by two principles: normal phase and reversal phase chromatography. In the case of NP-HPLC, a polar stationary phase is used, for example, silicon gel. In this process, the polarity determines the elution force of the mobile phase. The solvents are getting arranged by rising polarity, resulting in the so-called eluotropic series. This means that substances with higher polarity elute faster. Polar molecules better interact with the polar stationary phase and remain therefore longer in the column. RP-HPLC applies a non-polar stationary phase. The elution force decreases with rising polarity.Classification of HPLC
In HPLC, several separation mechanisms can be distinguished, depending on the kind of interaction between stationary phase, mobile phase and the sample: adsorption, partition, ion exchange, size exclusion and bioaffinity chromatography. However, adsorption and partition chromatography are the most common modes of HPLC.Architecture of an HPLC system
An HPLC system consists of an eluent vessel, a degasser, a pump, an injection valve, a precolumn, a column, a detector and an evaluation unit.Literature
- http://de.wikipedia.org/w/index.php?title=Hochleistungsfl%C3%BCssigkeitschromatographie&oldid=86523806 (called: 30.03.11).